Correlation between electrical and hemodynamic responses during visual stimulation with graded contrasts | |
Si, Juanning1,2; Zhang, Xin1,2; Li, Yuejun3; Zhang, Yujin1,2; Zuo, Nianming1,2; Jiang, Tianzi1,2,3,4,5; Tianzi Jiang | |
发表期刊 | JOURNAL OF BIOMEDICAL OPTICS |
2016-09-01 | |
卷号 | 21期号:9页码:091315 |
文章类型 | Article |
摘要 | Brain functional activity involves complex cellular, metabolic, and vascular chain reactions, making it difficult to comprehend. Electroencephalography (EEG) and functional near infrared spectroscopy (fNIRS) have been combined into a multimodal neuroimaging method that captures both electrophysiological and hemo-dynamic information to explore the spatiotemporal characteristics of brain activity. Because of the significance of visually evoked functional activity in clinical applications, numerous studies have explored the amplitude of the visual evoked potential (VEP) to clarify its relationship with the hemodynamic response. However, relatively few studies have investigated the influence of latency, which has been frequently used to diagnose visual diseases, on the hemodynamic response. Moreover, because the latency and the amplitude of VEPs have different roles in coding visual information, investigating the relationship between latency and the hemodynamic response should be helpful. In this study, checkerboard reversal tasks with graded contrasts were used to evoke visual functional activity. Both EEG and fNIRS were employed to investigate the relationship between neuronal electrophysiological activities and the hemodynamic responses. The VEP amplitudes were linearly correlated with the hemodynamic response, but the VEP latency showed a negative linear correlation with the hemodynamic response. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE) |
关键词 | Electroencephalography Functional Near Infrared Spectroscopy Visual Evoked Potential Visual Contrast Latency |
WOS标题词 | Science & Technology ; Life Sciences & Biomedicine ; Physical Sciences |
DOI | 10.1117/1.JBO.21.9.091315 |
关键词[WOS] | NEAR-INFRARED SPECTROSCOPY ; BRAIN COMPUTER-INTERFACE ; EVOKED-POTENTIALS ; BOLD RESPONSE ; REACTION-TIME ; NEURAL BASIS ; EEG-FMRI ; CORTEX ; STIMULUS ; LATENCY |
收录类别 | SCI |
语种 | 英语 |
项目资助者 | National Key Scientific Instrument and Equipment Development Project of China(2012YQ120046) ; Natural Science Foundation of China(31571003) |
WOS研究方向 | Biochemistry & Molecular Biology ; Optics ; Radiology, Nuclear Medicine & Medical Imaging |
WOS类目 | Biochemical Research Methods ; Optics ; Radiology, Nuclear Medicine & Medical Imaging |
WOS记录号 | WOS:000388212700022 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ia.ac.cn/handle/173211/12012 |
专题 | 脑网络组研究 中国科学院自动化研究所 |
通讯作者 | Tianzi Jiang |
作者单位 | 1.Chinese Acad Sci, Inst Automat, Brainnetome Ctr, Beijing 100190, Peoples R China 2.Chinese Acad Sci, Natl Lab Pattern Recognit, Inst Automat, Beijing 100190, Peoples R China 3.Univ Elect Sci & Technol China, Key Lab NeuroInformat, Minist Educ, Sch Life Sci & Technol, Chengdu 625014, Peoples R China 4.Chinese Acad Sci, CAS Ctr Excellence Brain Sci, Inst Automat, Beijing 100190, Peoples R China 5.Univ Queensland, Queensland Brain Inst, St Lucia, Qld 4072, Australia |
第一作者单位 | 中国科学院自动化研究所; 模式识别国家重点实验室 |
推荐引用方式 GB/T 7714 | Si, Juanning,Zhang, Xin,Li, Yuejun,et al. Correlation between electrical and hemodynamic responses during visual stimulation with graded contrasts[J]. JOURNAL OF BIOMEDICAL OPTICS,2016,21(9):091315. |
APA | Si, Juanning.,Zhang, Xin.,Li, Yuejun.,Zhang, Yujin.,Zuo, Nianming.,...&Tianzi Jiang.(2016).Correlation between electrical and hemodynamic responses during visual stimulation with graded contrasts.JOURNAL OF BIOMEDICAL OPTICS,21(9),091315. |
MLA | Si, Juanning,et al."Correlation between electrical and hemodynamic responses during visual stimulation with graded contrasts".JOURNAL OF BIOMEDICAL OPTICS 21.9(2016):091315. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
JBO_21_9_091315.pdf(4071KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论