摘要 | This study aimed to investigate the impact of delivery characteristics on the dose delivery accuracy of volumetric modulated arc therapy (VMAT) for different treatment sites. The pretreatment quality assurance (QA) results of 344 VMAT patients diagnosed with gynecological (GYN), head and neck (H&N), rectal or prostate cancer were randomly chosen in this study. Ten metrics reflecting VMAT delivery characteristics were extracted from the QA plans. Compared with GYN and rectal plans, H&N and prostate plans had higher aperture complexity and monitor units (MU), and smaller aperture area. Prostate plans had the smallest aperture area and lowest leaf speed compared with other plans (P < 0.001). No differences in gantry speed were found among the four sites. The gamma passing rates (GPRs) of GYN, rectal and H&N plans were inversely associated with union aperture area (UAA) and leaf speed (Pearson's r: -0.39 to -0.68). GPRs of prostate plans were inversely correlated with aperture complexity, MU and small aperture score (SAS) (absolute Pearson's r: 0.34 to 0.49). Significant differences in GPR between high SAS and low SAS subgroups were found only when leaf speed was <0.42 cm s-1 (P < 0.001). No association of GPR with gantry speed was found in four sites. Leaf speed was more strongly associated with UAA. Aperture complexity and MU were more strongly associated with SAS. VMAT plans from different sites have distinct delivery characteristics. Affecting dose delivery accuracy, leaf speed is the key factor for GYN, rectal and H&N plans, while aperture complexity, MU and small apertures have a higher influence on prostate plans. |
关键词 | complexity metrics volumetric modulated arc therapy quality assurance gamma passing rate |
收录类别 | SCI |
语种 | 英语 |
资助项目 | National natural Science Foundation of China[81071237] ; National natural Science Foundation of China[81071237] |
WOS研究方向 | Radiology, Nuclear Medicine & Medical Imaging |
WOS类目 | Radiology, Nuclear Medicine & Medical Imaging |
WOS记录号 | WOS:000471277703319 |
出版者 | WILEY |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ia.ac.cn/handle/173211/25997 |
专题 | 脑图谱与类脑智能实验室_脑网络组研究 |
作者单位 | 1.Peking Univ, Hosp 3, Beijing, Peoples R China 2.Chinese Acad Sci, Inst Automat, Beijing, Peoples R China 3.Mem Sloan Kettering Canc Ctr, Basking Ridge, NJ USA |
推荐引用方式 GB/T 7714 | Li, J.,Zhang, X.,Li, J.,et al. Impact of Delivery Characteristics On Dose Delivery Accuracy of Volumetric Modulated Arc Therapy for Different Treatment Sites[J]. MEDICAL PHYSICS,2019,46(6):E484-E484. |
APA | Li, J..,Zhang, X..,Li, J..,Jiang, R..,Sui, J..,...&Yang, R..(2019).Impact of Delivery Characteristics On Dose Delivery Accuracy of Volumetric Modulated Arc Therapy for Different Treatment Sites.MEDICAL PHYSICS,46(6),E484-E484. |
MLA | Li, J.,et al."Impact of Delivery Characteristics On Dose Delivery Accuracy of Volumetric Modulated Arc Therapy for Different Treatment Sites".MEDICAL PHYSICS 46.6(2019):E484-E484. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Impact of delivery c(612KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Li, J.]的文章 |
[Zhang, X.]的文章 |
[Li, J.]的文章 |
百度学术 |
百度学术中相似的文章 |
[Li, J.]的文章 |
[Zhang, X.]的文章 |
[Li, J.]的文章 |
必应学术 |
必应学术中相似的文章 |
[Li, J.]的文章 |
[Zhang, X.]的文章 |
[Li, J.]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论