CASIA OpenIR  > 中国科学院分子影像重点实验室
Experimental Cerenkov luminescence tomography of the mouse model with SPECT imaging validation
Hu, Zhenhua1; Liang, Jimin1; Yang, Weidong2; Fan, Weiwei3; Li, Congye3; Ma, Xiaowei2; Chen, Xueli1; Ma, Xiaopeng1; Li, Xiangsi1; Qu, Xiaochao1; Wang, Jing2; Cao, Feng3; Tian, Jie1,4
发表期刊OPTICS EXPRESS
2010-11-22
卷号18期号:24页码:24441-24450
文章类型Article
摘要Optical molecular imaging resulting from Cerenkov radiation has become a motivating topic recently and will potentially open new avenues for the study of small animal imaging. Cerenkov-based optical imaging taken from living animals in vivo has been studied with two-dimensional (2D) planar geometry and three-dimensional (3D) homogeneous mouse model. In this study, we performed 3D Cerenkov-based luminescence tomography (CLT) using a heterogeneous mouse model with an implanted Na(131)I radioactive source, which provided the accurate location for the reconstructed source. Furthermore, single photon emission computed tomography (SPECT) was utilized to verify the results of 3D CLT. We reconstructed the localization and intensity of an embedded radioactive source with various concentrations, and established a quantitative relationship between the radiotracer activity and the reconstructed intensity. The results showed the ability of in vivo CLT to recover the radioactive probe distribution in the heterogeneous mouse model and the potential of a SPECT imaging validation strategy to verify the results of optical molecular tomography. (C) 2010 Optical Society of America
关键词Medical And Biological Imaging Tomography Luminescence Functional Monitoring And Imaging Light Propagation In Tissues
WOS标题词Science & Technology ; Physical Sciences
关键词[WOS]POSITRON-EMITTING RADIOTRACERS ; FINITE-ELEMENT ALGORITHM ; BIOLUMINESCENCE TOMOGRAPHY ; FLUORESCENCE TOMOGRAPHY ; RECONSTRUCTION ; LIGHT ; RADIATION ; SYSTEM
收录类别SCI
语种英语
WOS研究方向Optics
WOS类目Optics
WOS记录号WOS:000285586800058
引用统计
被引频次:109[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ia.ac.cn/handle/173211/3934
专题中国科学院分子影像重点实验室
通讯作者Wang, Jing
作者单位1.Xidian Univ, Life Sci Res Ctr, Sch Life Sci & Technol, Xian 710071, Peoples R China
2.Fourth Mil Med Univ, Dept Nucl Med, Xijing Hosp, Xian 710032, Peoples R China
3.Fourth Mil Med Univ, Dept Cardiol, Xijing Hosp, Xian 710032, Peoples R China
4.Chinese Acad Sci, Inst Automat, Beijing 100190, Peoples R China
推荐引用方式
GB/T 7714
Hu, Zhenhua,Liang, Jimin,Yang, Weidong,et al. Experimental Cerenkov luminescence tomography of the mouse model with SPECT imaging validation[J]. OPTICS EXPRESS,2010,18(24):24441-24450.
APA Hu, Zhenhua.,Liang, Jimin.,Yang, Weidong.,Fan, Weiwei.,Li, Congye.,...&Tian, Jie.(2010).Experimental Cerenkov luminescence tomography of the mouse model with SPECT imaging validation.OPTICS EXPRESS,18(24),24441-24450.
MLA Hu, Zhenhua,et al."Experimental Cerenkov luminescence tomography of the mouse model with SPECT imaging validation".OPTICS EXPRESS 18.24(2010):24441-24450.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Experimental Cerenko(1072KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Hu, Zhenhua]的文章
[Liang, Jimin]的文章
[Yang, Weidong]的文章
百度学术
百度学术中相似的文章
[Hu, Zhenhua]的文章
[Liang, Jimin]的文章
[Yang, Weidong]的文章
必应学术
必应学术中相似的文章
[Hu, Zhenhua]的文章
[Liang, Jimin]的文章
[Yang, Weidong]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Experimental Cerenkov luminescence tomography of the mouse model with SPECT imaging validation. - Optics express.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。