CASIA OpenIR  > 中国科学院分子影像重点实验室
Probability method for Cerenkov luminescence tomography based on conformance error minimization
Ding, Xintao1,2; Wang, Kun3; Jie, Biao2; Luo, Yonglong2; Hu, Zhenhua3; Tian, Jie3
发表期刊BIOMEDICAL OPTICS EXPRESS
2014-07-01
卷号5期号:7页码:2091-2112
文章类型Article
摘要Cerenkov luminescence tomography (CLT) was developed to reconstruct a three-dimensional (3D) distribution of radioactive probes inside a living animal. Reconstruction methods are generally performed within a unique framework by searching for the optimum solution. However, the ill-posed aspect of the inverse problem usually results in the reconstruction being non-robust. In addition, the reconstructed result may not match reality since the difference between the highest and lowest uptakes of the resulting radiotracers may be considerably large, therefore the biological significance is lost. In this paper, based on the minimization of a conformance error, a probability method is proposed that consists of qualitative and quantitative modules. The proposed method first pinpoints the organ that contains the light source. Next, we developed a 0-1 linear optimization subject to a space constraint to model the CLT inverse problem, which was transformed into a forward problem by employing a region growing method to solve the optimization. After running through all of the elements used to grow the sources, a source sequence was obtained. Finally, the probability of each discrete node being the light source inside the organ was reconstructed. One numerical study and two in vivo experiments were conducted to verify the performance of the proposed algorithm, and comparisons were carried out using the hp-finite element method (hp-FEM). The results suggested that our proposed probability method was more robust and reasonable than hp-FEM. (C) 2014 Optical Society of America
关键词-
WOS标题词Science & Technology ; Life Sciences & Biomedicine ; Physical Sciences
关键词[WOS]POSITRON-EMITTING RADIOTRACERS ; BIOLUMINESCENCE TOMOGRAPHY ; FLUORESCENCE TOMOGRAPHY ; RECONSTRUCTION METHOD ; OPTICAL-PROPERTIES ; CONDITION NUMBERS ; INVERSE PROBLEMS ; RADIATION ; LIGHT ; MODEL
收录类别SCI
语种英语
WOS研究方向Biochemistry & Molecular Biology ; Optics ; Radiology, Nuclear Medicine & Medical Imaging
WOS类目Biochemical Research Methods ; Optics ; Radiology, Nuclear Medicine & Medical Imaging
WOS记录号WOS:000338929100009
引用统计
被引频次:25[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ia.ac.cn/handle/173211/4035
专题中国科学院分子影像重点实验室
通讯作者Hu, Zhenhua
作者单位1.Anhui Normal Univ, Sch Terr Resources & Tourism, Wuhu 241003, Anhui, Peoples R China
2.Anhui Normal Univ, Sch Math & Comp Sci, Wuhu 241003, Anhui, Peoples R China
3.Chinese Acad Sci, Inst Automat, Key Lab Mol Imaging, Beijing 100190, Peoples R China
通讯作者单位中国科学院自动化研究所
推荐引用方式
GB/T 7714
Ding, Xintao,Wang, Kun,Jie, Biao,et al. Probability method for Cerenkov luminescence tomography based on conformance error minimization[J]. BIOMEDICAL OPTICS EXPRESS,2014,5(7):2091-2112.
APA Ding, Xintao,Wang, Kun,Jie, Biao,Luo, Yonglong,Hu, Zhenhua,&Tian, Jie.(2014).Probability method for Cerenkov luminescence tomography based on conformance error minimization.BIOMEDICAL OPTICS EXPRESS,5(7),2091-2112.
MLA Ding, Xintao,et al."Probability method for Cerenkov luminescence tomography based on conformance error minimization".BIOMEDICAL OPTICS EXPRESS 5.7(2014):2091-2112.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Probability method f(595KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Ding, Xintao]的文章
[Wang, Kun]的文章
[Jie, Biao]的文章
百度学术
百度学术中相似的文章
[Ding, Xintao]的文章
[Wang, Kun]的文章
[Jie, Biao]的文章
必应学术
必应学术中相似的文章
[Ding, Xintao]的文章
[Wang, Kun]的文章
[Jie, Biao]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Probability method for Cerenkov luminescence tomography based on conformance error minimization - Biomedical Optics Express.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。