Comparative studies of l(p)-regularization-based reconstruction algorithms for bioluminescence tomography
Zhang, Qitan1; Chen, Xueli1; Qu, Xiaochao1; Liang, Jimin1; Tian, Jie1,2
发表期刊BIOMEDICAL OPTICS EXPRESS
2012-11-01
卷号3期号:11页码:2916-2936
文章类型Article
摘要Inverse source reconstruction is the most challenging aspect of bioluminescence tomography (BLT) because of its ill-posedness. Although many efforts have been devoted to this problem, so far, there is no generally accepted method. Due to the ill-posedness property of the BLT inverse problem, the regularization method plays an important role in the inverse reconstruction. In this paper, six reconstruction algorithms based on l(p) regularization are surveyed. The effects of the permissible source region, measurement noise, optical properties, tissue specificity and source locations on the performance of the reconstruction algorithms are investigated using a series of single source experiments. In order to further inspect the performance of the reconstruction algorithms, we present the double sources and the in vivo mouse experiments to study their resolution ability and potential for a practical heterogeneous mouse experiment. It is hoped to provide useful guidance on algorithm development and application in the related fields. (C) 2012 Optical Society of America
WOS标题词Science & Technology ; Life Sciences & Biomedicine ; Physical Sciences
关键词[WOS]OPTICAL TOMOGRAPHY ; MODEL ; REGULARIZATION ; EQUATIONS ; MOUSE ; LIGHT
收录类别SCI
语种英语
WOS研究方向Biochemistry & Molecular Biology ; Optics ; Radiology, Nuclear Medicine & Medical Imaging
WOS类目Biochemical Research Methods ; Optics ; Radiology, Nuclear Medicine & Medical Imaging
WOS记录号WOS:000310644700022
引用统计
被引频次:19[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ia.ac.cn/handle/173211/4038
专题中国科学院分子影像重点实验室
作者单位1.Xidian Univ, Sch Life Sci & Technol, Xian 710071, Shaanxi, Peoples R China
2.Chinese Acad Sci, Inst Automat, Beijing 100190, Peoples R China
推荐引用方式
GB/T 7714
Zhang, Qitan,Chen, Xueli,Qu, Xiaochao,et al. Comparative studies of l(p)-regularization-based reconstruction algorithms for bioluminescence tomography[J]. BIOMEDICAL OPTICS EXPRESS,2012,3(11):2916-2936.
APA Zhang, Qitan,Chen, Xueli,Qu, Xiaochao,Liang, Jimin,&Tian, Jie.(2012).Comparative studies of l(p)-regularization-based reconstruction algorithms for bioluminescence tomography.BIOMEDICAL OPTICS EXPRESS,3(11),2916-2936.
MLA Zhang, Qitan,et al."Comparative studies of l(p)-regularization-based reconstruction algorithms for bioluminescence tomography".BIOMEDICAL OPTICS EXPRESS 3.11(2012):2916-2936.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
40.BOE(2012).pdf(5003KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang, Qitan]的文章
[Chen, Xueli]的文章
[Qu, Xiaochao]的文章
百度学术
百度学术中相似的文章
[Zhang, Qitan]的文章
[Chen, Xueli]的文章
[Qu, Xiaochao]的文章
必应学术
必应学术中相似的文章
[Zhang, Qitan]的文章
[Chen, Xueli]的文章
[Qu, Xiaochao]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 40.BOE(2012).pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。