Institutional Repository of Chinese Acad Sci, Inst Automat, CAS Key Lab Mol Imaging, Beijing 100190, Peoples R China
Automated Motion Correction for In Vivo Optical Projection Tomography | |
Zhu, Shouping4; Dong, Di2![]() | |
发表期刊 | IEEE TRANSACTIONS ON MEDICAL IMAGING
![]() |
2012-07-01 | |
卷号 | 31期号:7页码:1358-1371 |
文章类型 | Article |
摘要 | In in vivo optical projection tomography (OPT), object motion will significantly reduce the quality and resolution of the reconstructed image. Based on the well-known Helgason-Ludwig consistency condition (HLCC), we propose a novel method for motion correction in OPT under parallel beam illumination. The method estimates object motion from projection data directly and does not require any other additional information, which results in a straightforward implementation. We decompose object movement into translation and rotation, and discuss how to correct for both translation and general motion simultaneously. Since finding the center of rotation accurately is critical in OPT, we also point out that the system's geometrical offset can be considered as object translation and therefore also calibrated through the translation estimation method. In order to verify the algorithm effectiveness, both simulated and in vivo OPT experiments are performed. Our results demonstrate that the proposed approach is capable of decreasing movement artifacts significantly thus providing high quality reconstructed images in the presence of object motion. |
关键词 | Helgason-ludwig Consistency Condition (Hlcc) Motion Correction Optical Projection Tomography (Opt) |
WOS标题词 | Science & Technology ; Technology ; Life Sciences & Biomedicine |
关键词[WOS] | FAN-BEAM CT ; COMPUTED-TOMOGRAPHY ; ARTIFACT REDUCTION ; IMAGE QUALITY ; TRANSMISSION ; QUANTIFICATION ; OPTIMIZATION ; MICROSCOPY ; ALGORITHM ; TOOL |
收录类别 | SCI |
语种 | 英语 |
WOS研究方向 | Computer Science ; Engineering ; Imaging Science & Photographic Technology ; Radiology, Nuclear Medicine & Medical Imaging |
WOS类目 | Computer Science, Interdisciplinary Applications ; Engineering, Biomedical ; Engineering, Electrical & Electronic ; Imaging Science & Photographic Technology ; Radiology, Nuclear Medicine & Medical Imaging |
WOS记录号 | WOS:000305898500003 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ia.ac.cn/handle/173211/4065 |
专题 | 中国科学院分子影像重点实验室 |
作者单位 | 1.Fdn Res & Technol Hellas FORTH, Inst Elect Struct & Laser, Iraklion 71110, Greece 2.Chinese Acad Sci, Inst Automat, Intelligent Med Res Ctr, Beijing 100190, Peoples R China 3.Fdn Res & Technol Hellas FORTH, Inst Mol Biol & Biotechnol, Iraklion 71110, Greece 4.Xidian Univ, Sch Life Sci & Technol, Xian 710071, Shaanxi, Peoples R China 5.Univ Heidelberg, Kirchhoff Inst Phys, D-69120 Heidelberg, Germany |
推荐引用方式 GB/T 7714 | Zhu, Shouping,Dong, Di,Birk, Udo Jochen,et al. Automated Motion Correction for In Vivo Optical Projection Tomography[J]. IEEE TRANSACTIONS ON MEDICAL IMAGING,2012,31(7):1358-1371. |
APA | Zhu, Shouping.,Dong, Di.,Birk, Udo Jochen.,Rieckher, Matthias.,Tavernarakis, Nektarios.,...&Ripoll, Jorge.(2012).Automated Motion Correction for In Vivo Optical Projection Tomography.IEEE TRANSACTIONS ON MEDICAL IMAGING,31(7),1358-1371. |
MLA | Zhu, Shouping,et al."Automated Motion Correction for In Vivo Optical Projection Tomography".IEEE TRANSACTIONS ON MEDICAL IMAGING 31.7(2012):1358-1371. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
zhushoupingTMI.pdf(3468KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |