A Segmentation Algorithm for Quantitative Analysis of Heterogeneous Tumors of the Cervix With F-18-FDG PET/CT
Mu, Wei1; Chen, Zhe1; Shen, Wei1; Yang, Feng2; Liang, Ying3; Dai, Ruwei1; Wu, Ning3; Tian, Jie1
Source PublicationIEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
2015-10-01
Volume62Issue:10Pages:2465-2479
SubtypeArticle
AbstractAs positron-emission tomography (PET) images have low spatial resolution and much noise, accurate image segmentation is one of the most challenging issues in tumor quantification. Tumors of the uterine cervix present a particular challenge because of urine activity in the adjacent bladder. Here, we propose and validate an automatic segmentation method adapted to cervical tumors. Our proposed methodology combined the gradient field information of both the filtered PET image and the level set function into a level set framework by constructing a new evolution equation. Furthermore, we also constructed a new hyperimage to recognize a rough tumor region using the fuzzy c-means algorithm according to the tissue specificity as defined by both PET (uptake) and computed tomography (attenuation) to provide the initial zero level set, which could make the segmentation process fully automatic. The proposed method was verified based on simulation and clinical studies. For simulation studies, seven different phantoms, representing tumors with homogenous/heterogeneous-low/high uptake patterns and different volumes, were simulated with five different noise levels. Twenty-seven cervical cancer patients at different stages were enrolled for clinical evaluation of the method. Dice similarity coefficients (DSC) and Hausdorff distance (HD) were used to evaluate the accuracy of the segmentation method, while a Bland-Altman analysis of the mean standardized uptake value (SUVmean) and metabolic tumor volume (MTV) was used to evaluate the accuracy of the quantification. Using this method, the DSCs and HDs of the homogenous and heterogeneous phantoms under clinical noise level were 93.39 +/- 1.09% and 6.02 +/- 1.09 mm, 93.59 +/- 1.63% and 8.92 +/- 2.57 mm, respectively. The DSCs and HDs in patients measured 91.80 +/- 2.46% and 7.79 +/- 2.18 mm. Through Bland-Altman analysis, the SUVmean and the MTV using our method showed high correlation with the clinical gold standard. The results of both simulation and clinical studies demonstrated the accuracy, effectiveness, and robustness of the proposed method. Further assessment of the quantitative indices indicates the feasibility of this algorithm in accurate quantitative analysis of cervical tumors in clinical practice.
KeywordCervical Tumor Segmentation Fuzzy-c-means (Fcm) Improved Level Set Method Positron-emission Tomography/computed Tomography (Pet/ct) Images
WOS HeadingsScience & Technology ; Technology
DOI10.1109/TBME.2015.2433397
WOS KeywordTEXTURE ANALYSIS ; ACTIVE CONTOURS ; FDG-PET ; CANCER ; IMAGES ; VOLUME ; QUANTIFICATION ; CT ; DELINEATION ; THERAPY
Indexed BySCI
Language英语
WOS Research AreaEngineering
WOS SubjectEngineering, Biomedical
WOS IDWOS:000361701300014
Citation statistics
Cited Times:8[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.ia.ac.cn/handle/173211/9018
Collection中国科学院分子影像重点实验室
Affiliation1.Chinese Acad Sci, Inst Automat, Key Lab Mol Imaging, Beijing 100190, Peoples R China
2.Beijing Jiaotong Univ, Sch Comp & Informat Technol, Beijing, Peoples R China
3.Chinese Acad Med Sci, Canc Inst & Hosp, Beijing 100190, Peoples R China
Recommended Citation
GB/T 7714
Mu, Wei,Chen, Zhe,Shen, Wei,et al. A Segmentation Algorithm for Quantitative Analysis of Heterogeneous Tumors of the Cervix With F-18-FDG PET/CT[J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING,2015,62(10):2465-2479.
APA Mu, Wei.,Chen, Zhe.,Shen, Wei.,Yang, Feng.,Liang, Ying.,...&Tian, Jie.(2015).A Segmentation Algorithm for Quantitative Analysis of Heterogeneous Tumors of the Cervix With F-18-FDG PET/CT.IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING,62(10),2465-2479.
MLA Mu, Wei,et al."A Segmentation Algorithm for Quantitative Analysis of Heterogeneous Tumors of the Cervix With F-18-FDG PET/CT".IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING 62.10(2015):2465-2479.
Files in This Item: Download All
File Name/Size DocType Version Access License
A Segmentation Algor(1769KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Mu, Wei]'s Articles
[Chen, Zhe]'s Articles
[Shen, Wei]'s Articles
Baidu academic
Similar articles in Baidu academic
[Mu, Wei]'s Articles
[Chen, Zhe]'s Articles
[Shen, Wei]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Mu, Wei]'s Articles
[Chen, Zhe]'s Articles
[Shen, Wei]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: A Segmentation Algorithm for Quantitative Analysis of Heterogeneous Tumors of the Cervix with 18F-FDG PETCT.pdf
Format: Adobe PDF
This file does not support browsing at this time
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.