摘要 | QRS detection is an important step in electrocardiogram signal processing and analysis. Despite a lot of research effort, robustness and high detection accuracy still remain open problems. Here we present a real-time QRS detector, based on wavelet decomposition and spline interpolation, which is working in our portable health monitor system (PHMS). The discrete wavelet transform combined with the Cubic Spline Interpolation is used as the preprocessor. An improved dynamic weights adjusting strategy is adopted to enhance the detection robustness. Finally, peak detector and adaptive threshold detector are used to determine the R fiducial point. We tested the algorithm against the Massachusetts Institute of Technology-Beth Israel Hosptial (MIT-BIH) arrhythmia database, and achieved a sensitivity of 99.75% and positive prediction of 99.83%. Further experiments carried out in the PHMS showed the robustness and sound performance in processing real-time sampled signal despite heavy noise. Time accuracy was also taken into consideration in the test and the total root mean square error was 16.03 ms. |
关键词 | Ecg Qrs Detector Telemedicine Wavelet Spline Interpolation |
WOS标题词 | Science & Technology ; Life Sciences & Biomedicine |
收录类别 | SCI |
语种 | 英语 |
WOS研究方向 | Health Care Sciences & Services |
WOS类目 | Health Care Sciences & Services |
WOS记录号 | WOS:000266169600045 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ia.ac.cn/handle/173211/9568 |
专题 | 09年以前成果 |
作者单位 | Chinese Acad Sci, Grad Univ, Inst Automat, CAS, Beijing 100190, Peoples R China |
推荐引用方式 GB/T 7714 | Zheng, Huabin,Wu, Jiankang. A Real-Time QRS Detector Based on Discrete Wavelet Transform and Cubic Spline Interpolation[J]. TELEMEDICINE JOURNAL AND E-HEALTH,2008,14(8):809-815. |
APA | Zheng, Huabin,&Wu, Jiankang.(2008).A Real-Time QRS Detector Based on Discrete Wavelet Transform and Cubic Spline Interpolation.TELEMEDICINE JOURNAL AND E-HEALTH,14(8),809-815. |
MLA | Zheng, Huabin,et al."A Real-Time QRS Detector Based on Discrete Wavelet Transform and Cubic Spline Interpolation".TELEMEDICINE JOURNAL AND E-HEALTH 14.8(2008):809-815. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Zheng, Huabin]的文章 |
[Wu, Jiankang]的文章 |
百度学术 |
百度学术中相似的文章 |
[Zheng, Huabin]的文章 |
[Wu, Jiankang]的文章 |
必应学术 |
必应学术中相似的文章 |
[Zheng, Huabin]的文章 |
[Wu, Jiankang]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论