AbstractPurpose: The appearance of x-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging by x ray. In the previous XLCT system, the sample was irradiated by a sequence of narrow x-ray beams and the x-ray luminescence was measured by a highly sensitive charge coupled device (CCD) camera. This resulted in a relatively long sampling time and relatively low utilization of the x-ray beam. In this paper, a novel cone beam x-ray luminescence computed tomography strategy is proposed, which can fully utilize the x-ray dose and shorten the scanning time. The imaging model and reconstruction method are described. The validity of the imaging strategy has been studied in this paper.
KeywordCone Beam X-ray Luminescence Computed Tomography 3d Reconstruction
WOS HeadingsScience & Technology ; Life Sciences & Biomedicine
WOS KeywordMULTISPECTRAL BIOLUMINESCENCE TOMOGRAPHY ; PERMISSIBLE SOURCE REGION ; FINITE-ELEMENT ALGORITHM ; RECONSTRUCTION ; METHODOLOGY ; EXCITATION ; STRATEGY ; CT
Indexed BySCI
Language英语
WOS Research AreaRadiology, Nuclear Medicine & Medical Imaging
WOS SubjectRadiology, Nuclear Medicine & Medical Imaging
WOS IDWOS:000338348200012
Citation statistics
Cited Times:54[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.ia.ac.cn/handle/173211/4086
Collection中国科学院分子影像重点实验室
Corresponding AuthorTian, Jie
Affiliation1.Xidian Univ, Sch Life Sci & Technol, Xian 710071, Peoples R China
2.Chinese Acad Sci, Inst Automat, Med Image Proc Grp, Beijing 100190, Peoples R China
Corresponding Author AffilicationInstitute of Automation, Chinese Academy of Sciences
Recommended Citation
GB/T 7714
Chen, Dongmei,Zhu, Shouping,Yi, Huangjian,et al. Cone beam x-ray luminescence computed tomography: A feasibility study[J]. MEDICAL PHYSICS,2013,40(3):-.
APA Chen, Dongmei.,Zhu, Shouping.,Yi, Huangjian.,Zhang, Xianghan.,Chen, Duofang.,...&Tian, Jie.(2013).Cone beam x-ray luminescence computed tomography: A feasibility study.MEDICAL PHYSICS,40(3),-.
MLA Chen, Dongmei,et al."Cone beam x-ray luminescence computed tomography: A feasibility study".MEDICAL PHYSICS 40.3(2013):-.
Files in This Item: Download All
File Name/Size DocType Version Access License
153.Medical Physics((2605KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Chen, Dongmei]'s Articles
[Zhu, Shouping]'s Articles
[Yi, Huangjian]'s Articles
Baidu academic
Similar articles in Baidu academic
[Chen, Dongmei]'s Articles
[Zhu, Shouping]'s Articles
[Yi, Huangjian]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Chen, Dongmei]'s Articles
[Zhu, Shouping]'s Articles
[Yi, Huangjian]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: 153.Medical Physics(2013).pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.