摘要 | An automatic approach based on microscopic visual control is proposed for a microassembly task, which is to insert a 10-mu m-diameter glass tube into a 12-mu m-diameter hole on a silicon substrate. A three-degree-of-freedom manipulator is used to control the motion of the glass tube. A microscopic camera is mounted on a movable platform toward the hole in the inclined direction similar to 30 deg from horizontal plane in order to view the hole and the tube. A calibration method based on active motions is designed to estimate the intrinsic and extrinsic parameters of the microscopic camera, which includes only two steps of motion of the tube's tip on the focal plane of the microscopic camera. The relative position errors are computed from the image feature errors and the parameters of the microscopic camera. A position-based control strategy is applied to align the tip to the position above the hole, which controls the tip to move to the hole along x, y, and z axes simultaneously. The tip is moved down a specified distance to insert into the hole after autofocus in order to improve the insertion accuracy. The experimental results verify the effectiveness of the proposed method. (C) 2014 Society of Photo-Optical Instrumentation Engineers (SPIE) |
关键词 | Feature Extraction Autofocus Calibration Microscopic Camera Visual Servoing Aligning Microassembly |
WOS标题词 | Science & Technology ; Physical Sciences |
关键词[WOS] | VISUAL MEASUREMENT ; VISION ; MODEL |
收录类别 | SCI |
语种 | 英语 |
WOS研究方向 | Optics |
WOS类目 | Optics |
WOS记录号 | WOS:000340680800021 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ia.ac.cn/handle/173211/3054 |
专题 | 中科院工业视觉智能装备工程实验室_精密感知与控制 |
作者单位 | Chinese Acad Sci, Res Ctr Precis Sensing & Control, Inst Automat, Beijing 100190, Peoples R China |
第一作者单位 | 精密感知与控制研究中心 |
推荐引用方式 GB/T 7714 | Li, Fudong,Xu, De,Shi, Yali,et al. Motion-based microscopic camera calibration and application on micro tube-hole insertion[J]. OPTICAL ENGINEERING,2014,53(5):053103-1-9. |
APA | Li, Fudong,Xu, De,Shi, Yali,&Zhang, Zhengtao.(2014).Motion-based microscopic camera calibration and application on micro tube-hole insertion.OPTICAL ENGINEERING,53(5),053103-1-9. |
MLA | Li, Fudong,et al."Motion-based microscopic camera calibration and application on micro tube-hole insertion".OPTICAL ENGINEERING 53.5(2014):053103-1-9. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Motion-based Microsc(2212KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论