A Robust Detection Method of Control Points for Calibration and Measurement With Defocused Images | |
Ding, Wendong1,2; Liu, Xilong1,2; Xu, De1,2; Zhang, Dapeng1,2; Zhang, Zhengtao1,2 | |
发表期刊 | IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT |
2017-10-01 | |
卷号 | 66期号:10页码:2725-2735 |
文章类型 | Article |
摘要 | This paper presents a detection method of control points for the camera calibration and measurement applications, which is robust to defocus. Our method is based on a ground truth, which we call ridge invariance. That is, the positions of broad-brush lines' ridge lines are invariant to defocus blur. First, the ridge invariance is deduced in theory. Then, the methods for ridge point's detection including defocus degree estimation and salience enhancement are deduced. In calibration and measurement experiments, new marks are designed and control points are determined at intersects of the ridge curves. Experiments show that our method can obtain precise calibration and measurement results with images in a large defocus amount range. In the effective defocus amount range, the accuracy of the proposed method almost keeps unchanged to the best values. The proposed method has approximated the same performance as conventional methods at good focus values. |
关键词 | Camera Calibration Control Point Detection Defocused Image Point Spread Function Vision Measurement |
WOS标题词 | Science & Technology ; Technology |
DOI | 10.1109/TIM.2017.2709561 |
关键词[WOS] | DIRECT LINEAR TRANSFORMATION ; LENS CAMERA CALIBRATION ; SINGLE IMAGE ; ACCURACY ; BLUR ; INSTRUMENT |
收录类别 | SCI |
语种 | 英语 |
项目资助者 | National Natural Science Foundation of China(61503376 ; special fund of Jiangsu Province for the transformation of scientific and technological achievements(BA2015144) ; 61227804 ; 61303177 ; 61421004) |
WOS研究方向 | Engineering ; Instruments & Instrumentation |
WOS类目 | Engineering, Electrical & Electronic ; Instruments & Instrumentation |
WOS记录号 | WOS:000411025400023 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ia.ac.cn/handle/173211/19812 |
专题 | 中科院工业视觉智能装备工程实验室_精密感知与控制 |
作者单位 | 1.Chinese Acad Sci, Inst Automat, Res Ctr Precis Sensing & Control, Beijing 100190, Peoples R China 2.Univ Chinese Acad Sci, Beijing 101408, Peoples R China |
第一作者单位 | 精密感知与控制研究中心 |
推荐引用方式 GB/T 7714 | Ding, Wendong,Liu, Xilong,Xu, De,et al. A Robust Detection Method of Control Points for Calibration and Measurement With Defocused Images[J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT,2017,66(10):2725-2735. |
APA | Ding, Wendong,Liu, Xilong,Xu, De,Zhang, Dapeng,&Zhang, Zhengtao.(2017).A Robust Detection Method of Control Points for Calibration and Measurement With Defocused Images.IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT,66(10),2725-2735. |
MLA | Ding, Wendong,et al."A Robust Detection Method of Control Points for Calibration and Measurement With Defocused Images".IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT 66.10(2017):2725-2735. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
07981379 A Robust De(2118KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论